Performing Manual Switchover
Manual switchover can be initiated from one of the node devices under different conditions, but is disabled during certain system processes.
Condition |
Manual Switchover Available |
|
---|---|---|
Active node device hardware failure in any of the following components:
|
Yes |
|
The standby node is unable to detect the active node. |
Yes, but can only initiate from the standby node |
|
The active node is unable to detect the standby node. |
No |
|
The system is setting up the initial HA configuration between the two devices. |
No |
|
The system is updating the firmware on both devices. |
No |
|
The system is syncing data between the node devices. |
Yes, but may cause data loss or unexpected errors |
|
All other situations |
Yes |
HA Manager begins the switchover process.