HA Requirements
To set up HA for your QNE devices, you must prepare the following items.
-
Two QNE devices with the following identical specifications and components:
-
Device model
Note:HA Manager currently supports QuCPE devices only.
-
Firmware version
-
CPU model
-
Memory capacity
-
Application disk specifications
-
Network module model
-
Number of power supply units
-
At least one 10 Gigabit or greater network port
-
-
One 10 Gigabit or greater network cable
Note:-
This cable connects the HA link ports between the QNE devices.
-
Both QNE devices must have the same HA link port number.
-
The HA link allows data detection and synchronization from the active node to the standby node.
-
-
Two network cables
Note:-
These cables connect the management port of each QNE device to the network. The management port allows you to access and manage the active node and standby node devices.
-
For each device, you must configure a static IP address for the management port. You can configure the static IP addresses during HA configuration.
-
Both QNE devices must have the same management port number.
-
-
Optional: Virtual IP address
Note:Setting up a virtual IP address allows you to maintain a constant connection to the active node no matter which device becomes the active node after a failover or switchover.