Configuring UPS Settings

  1. Go to Control Panel > System > UPS > UPS Settings.
  2. Select one of the following options and configure the settings.

    Mode

    User Actions

    USB connection

    1. Connect the UPS to the device using a USB cable.

    2. Select USB connection.

    3. Choose one of the following options.

      • Power off the server after the power fails for a specified time period

      • Allow the device to enter auto-protection mode after the power fails for a specified time period

      Note:

      In auto-protection mode, the device stops all services and unmounts all volumes to protect your data. After the power is restored, the device restarts and resumes normal operation.

    4. (Optional) Select Enable network UPS master and then specify the IP addresses to which QNE sends notifications in the event of power failure.

      Note:

      This option can only be selected when the UPS is connected to the device via USB.

    SNMP connection

    1. Connect the UPS to the same network as the device.

    2. Select SNMP connection.

    3. Specify the IP address of the UPS.

    4. Choose one of the following options.

      • Power off the server after the power fails for a specified time period

      • Allow the device to enter auto-protection mode after the power fails for a specified time period

    Network standby UPS

    1. Connect the UPS to the same network as the device.

    2. Select Network UPS slave.

    3. Specify the IP address of the UPS server.

    4. Choose one of the following options.

      • Power off the server after the power fails for a specified time period

      • Allow the device to enter auto-protection mode after the power fails for a specified time period

  3. Click Apply.