If this document does not correspond to your current software version, you can go to Download Center to find other available document versions.

QNAP

QuTS hero h6.0.x

Download (PDF)

NPIV service for high-availability clusters

iSCSI & Fibre Channel supports NPIV (N_Port ID Virtualization) service, which can help a high-availability (HA) cluster transfer Fibre Channel connections between node devices during failover or switchover.

To use Fibre Channel service in an HA cluster, the following conditions are required:

  • NPIV service is enabled.

    Note:

    When your device is part of an HA cluster, NPIV service is automatically enabled and cannot be disabled.

    For details on the NPIV service setting, see Fibre Channel Service in iSCSI & Fibre Channel global settings.

  • The following conditions are identical between the two cluster nodes:

    • The same Fibre Channel card model is installed in the same PCIe slot on both nodes.

    • On both nodes, each corresponding connection uses the same Fibre Channel port on each node.

    • The Fibre Channel port used by each corresponding connection must be configured with the same NPIV port WWPN between the nodes.

      To edit a port's NPIV port WWPN, see Fibre Channel port actions.

    • Both nodes must be connected to a network switch that supports Fibre Channel and NPIV.