The Uninterruptible Power Supply (UPS) events handled by the NAS during power disruptions include OnLine (OL), OnBattery (OB), OnSmartBoost (OSB), OFF (OFF), and OnBatteryTest (OBT). The NAS performs auto-protection or shutdown mode depending on the detected UPS status and your configured power failure settings. The following table describes the events and the corresponding NAS behavior.

UPS Event

Definition

NAS Status

NAS Action

OnLine (OL)

The UPS is operating normally.

Normal

None

OnSmartBoost (OSB)

The UPS is operating on smart boost mode.

Normal

None

OnBatteryTest (OBT)

The UPS is in battery test mode.

Normal

None

OnBattery (OB)

The UPS is operating on the backup battery.

Abnormal

The NAS enters auto-protection or shuts down.

OFF (OFF)

The UPS is not operating.

Abnormal

The NAS powers off.